Kay-Lit Engineering Consultancy
We offer all kinds of architectural, structural and Interior designs plus construction services
The client blamed the box house. The real problem? Poorly constructed box gutters.
With the right materials, proper detailing, and quality workmanship, box gutters don't leak, they last.
Home gym becomes a death sentence
🇺🇬 ❤️❤️
For years on site, we’ve been ordering ¾ aggregate because that’s what everyone uses, without ever asking why.
The answer is in Eurocode 2 (EN 1992-1-1, Clause 8.2 under placing and compaction of concrete.
The code limits the maximum aggregate size to Âľ of the minimum clear spacing between reinforcement bars or Âľ of the nominal concrete cover.
If the stones are bigger than the space meant for concrete to flow, they block, cause honeycombing, and weaken bond and durability.
So that familiar “¾” at the quarry isn’t a market rule, it’s geometry driven by reinforcement detailing and cover requirements.
❤️❤️ 🇺🇬
For years on site, we’ve been ordering ¾ aggregate because that’s what everyone uses, without ever asking why.
The answer is in Eurocode 2 (EN 1992-1-1, Clause 8.2 under placing and compaction of concrete.
The code limits the maximum aggregate size to Âľ of the minimum clear spacing between reinforcement bars or Âľ of the nominal concrete cover.
If the stones are bigger than the space meant for concrete to flow, they block, cause honeycombing, and weaken bond and durability.
So that familiar “¾” at the quarry isn’t a market rule, it’s geometry driven by reinforcement detailing and cover requirements.
This may look funny but it’s a common and dangerous practice.
Residential upper floors (Eurocode Category A) are designed for about 2.0 kN/m², not gym use.
Home gyms can impose 4 to 5 kN/m² plus dynamic impact from treadmills and weights.
A floor designed for a sofa can fail under exercise loads.
If it wasn’t designed for it, keep the gym on the ground floor.
No drawings, no concrete or reinforcement records.
So before building up, we verified the structure’s capacity and load path.
Category
Contact the business
Telephone
Website
Address
Naguru Drive Close
Kampala
Opening Hours
| Monday | 09:00 - 17:00 |
| Tuesday | 09:00 - 17:00 |
| Wednesday | 09:00 - 17:00 |
| Thursday | 09:00 - 17:00 |
| Friday | 09:00 - 17:00 |
| Saturday | 09:00 - 17:00 |
Alerts
Be the first to know and let us send you an email when Kay-Lit Engineering Consultancy posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.